-40%
Brand New Nexus 1262 High Performance Digital Power Meter 50% off Retail
$ 525.36
- Description
- Size Guide
Description
This item is brand new in the box and unopened from the manufacturer Electro Industries/ GaugeTech, visit their website to learn more about this product and it's capabilities.
The retail price of this product is 90.00, and we are selling these at 50% off the retail price while supplies last.
Nexus1262
Power Meter with Advanced Power Quality and RS-485 / RS-232 Communications
0.06% Watt/Hr Revenue Meter
Auto-Calibrating Metrology
Multi-Point CT & PT and Loss Compensation
Advanced Power Quality Recording
Eight Totalizing Registers
Data Logging & Event Recording
Unique Powerful Display Configurator
Multiple Communication Paths
Combination Modem & Ethernet
For Smart Grid and Intelligent Substation Applications
The Nexus 1262/1272 meters are designed for demanding smart grid and intelligent substation applications. They provide one of the most profound analyses of electricity available in a socket meter. The units offer extensive advanced monitoring features to meet the most critical power monitoring requirements. Using advanced DSP technology, the Nexus' measure immediate and stored revenue power data coupled with superior power quality and communication. To meet the sophisticated standards required by utility companies and de-regulated power providers, the Nexus' basic package starts where most other meters end. Standard features in Nexus units provide the ability to meet advanced metering needs for the future.
Accu-Measure™ Auto-calibrating metrology
EIG's Accu-Measure™ Auto-Calibrating Metrology provides unmatched accuracy.
Energy and Power Accuracy to Within 0.06%
Auto-calibration over Time
Automatic Temperature Drift Adjustments
4 Quadrant measurement
The unit is a full four quadrant meter and gathers hour data information in every quadrant.
kWh Delivered and Received
kVAh in Each Quadrant
kVARh in Each Quadrant
Q Hours
Time of Use
The 1262/1272 offers robust time of use functionality. Standard capabilities include:
8 TOU Schedules
4 Seasons/Year
20 Year Calendar
Prior Month and Prior Season
Programmable Freeze Registers
Transformer or Line Loss Compensation
Loss Compensation adjusts for both copper and iron losses with a simple user setup.
Field Test Mode
Test All Energy Readings
Enable/Disable in Test Mode
Preset Accumulators
Freezable Accumulators
Load Aggregation/Universal Metering
Using standard pulse inputs, the Nexus 1262/1272 can count pulses from external meters and accumulate usage. The pulse inputs can be used to totalize electrical usage and utility values, such as water or gas use data.
8 Pulse Inputs
Individual Accumulating Registers
4 Totalizing Registers (Add or Subtract)
CT & PT Compensation
The Nexus units compensate for errors in current transformers and potential transformers.
Voltage Compensation
Multipoint Current Compensation
Multipoint Phase Angle Compensation
Better than 0.01% Resolution
Multiple Demand Windows
The Nexus 1262/1272 simultaneously monitors five demand structures.
Block Window Demand
Rolling Window Demand
Predictive Demand
Thermal Demand
Cumulative Demand
Interval Length from 1 Second to Many Hours
End of Interval Pulse Output
End of Interval Pulse Input
Cold Load Pickup
Time Stamped Max. Demands
The units gather demand information for all power values. Each value is date/time stamped.
kW Demand, Delivered & Received, Max/Min
kVAR Demand, Delivered & Received, Max/Min
kVAR Coincident with kW Demand
kVA Demand, Max/Min
Amps Demand, Max/Min
Voltage, Max/Min
Unique Display Configurator
The Nexus 1262/1272 is designed with one of the industry's most advanced LCD display configuration technologies. With this highly customizable display, choose from multitudes of pre-programmed display screens and create fully customized displays for any specific application. Build, from scratch, user display screens as needed that provide information on anything the meter measures (which is almost everything). Use the display to view not only electrical, but water or gas usage. Also use the meter as an aggregator for total usage. Provide ambient and transformer temperature or any other desired critical operational data on the display.
3 Display Modes/75 Screen Slots
The meter's memory has 75 slots for custom and/or pre-programmed screens. These slots can be allocated to any view mode with any number of slots used in each of the modes.
Custom display configuration to Create Exactly What's Needed
Make Custom Screens Based on Modbus Registers
Make Any Custom Labels
Customize Screen Numbering and Order
Display Up To 5 Pieces of Information Per Screen
Display Water, Gas and Other Types of Usage
Add Diagnostic Information
Normal Mode
kWh Delivered and Received
kVARh Delivered and Received
kVAh Delivered and Received
Peak Rolling Window Demands
Peak Block Window Demand
Time of Use Mode
kWh and kW Demand Delivered and Received Total
kVARh and kVAR Demand Delivered and Received for Each Register
kVAh Delivered and Received for Each Register
kVAh Delivered and Received Total
Pre-configured Diagnostic Screens
Select from a large offering of diagnostic screens such as:
Voltages
Phase Angles
Harmonic Magnitudes
Firmware Versions
Meter Status
Phasor Diagram
Per Phase Amps
Watts/VARs
Many More Diagnostic Screens Available
Infrared Test Pulse
The meter provides an infrared test pulse that can pulse for +Watt-Hour, -Watt-Hour, +VAR-Hour, -VAR-Hour and VA-Hour. This pulse uses a time modulated pulse integration, allowing the pulse to be accurate during short duration pulse tests using industry accepted reference standards.
Standard multi-port Communications
Optical Port
2 RS485 Serial Ports
Modbus RTU/ASCII
DNP 3.0
Speeds Up to 115k bps
Optional Communications
Dial-Out modem (56k) with Battery Backed Outage Reporting
Ethernet 100BaseT
Ethernet/Modem combo
Combination Modem & Web Solution
This option allows you to access the meter through the web and through a modem for dial-up communication. Features include:
56k Modem
10/100BaseT Ethernet
Total Web Solutions (Web Server)
Email on Alarm
Does Not Support Battery for Outage Reporting
Standard I/O
IRIG-B 1 msec Time Synchronization to GPS Satellite Clock
4 Internal KYZ Pulse Outputs
8 KYZ Pulse/Status Inputs
Optional External I/O
Connect multiple external I/O Modules for enhanced I/O capability.
Analog Outputs
Analog Inputs
Digital Status Inputs
KYZ Outputs
Relay/Alarm Outputs
Control Capabilities
ElectroLogic™ Provides User-definable Control Outputs
Action and/or Alarm on Abnormal Condition
Action on Boolean Logic Combinations of Inputs or Electrical Conditions
DNP 3.0 Level 2 Plus
The Nexus 1262/1272 provides the industry's most advanced DNP 3.0 protocol implementations. DNP 3.0 is available on the serial and Ethernet ports. EIG's Nexus 1262/1272 complies with all DNP Level 1 and Level 2 certification requirements PLUS a host of additional features including:
Up to 136 Measurements:
64 Binary Inputs, 8 Binary Counters, 64 Analog Inputs Mapped to DNP Static Points in the Customizable DNP Point Map
Up to 16 Relays and 8 Resets
Can Be Controlled through DNP
Report-By-Exception Processing
(DNP Events) Deadbands Can Be Set on a Per-point Basis
250 Events in Combinations of Four Events:
Binary Input Change, Frozen Counter, Counter Change, Analog Change
Freeze Commands
: Freeze, Freeze/No-Ack, Freeze with Time, Freeze with Time/No-Ack, scheduled Freeze Command
Freeze with Time Command
: Enables the Nexus Meter to Have Internal Time-driven Frozen Counter and Frozen Counter Event data
Third Party Certification is Available
Total Web Solutions— Providing Advanced Metering Data Integration With the Web
Total Web Solutions is an advanced Ethernet communication architecture allowing you to design custom webpages, display metering data and host your meter power information website directly on a Nexus meter. The Nexus meter directly hosts the web data without any need for dedicated server software, ActiveX Controls or Java Applets. The meter does the data collection, the formatting and the page hosting.
Advanced Features Include:
Fully Customizable
Webpage Development
Direct Webpage Hosting With Live Readings
Multiple Meter Hosting
Read Direct From Meters (No Server Software Needed)
No Active Controls or Java Downloads
IT Dept Friendly. Works Through Firewalls; Low-Cost/High Functionality
Instant Alarm Emails – Direct from the Meter
WebExplorer (Directly Host Metering Data)
EIG's WebExplorer provides you with direct access to all power data through Internet Explorer in standard HTML format, without needing to download ActiveX controls or Java applets. WebExplorer is fully programmable, so you can customize your own SCADA quality webpages, graphics and configurations.
Easily Incorporated Into Any Existing Web Applications
Fully Programmable Webpage Generator
Brings in Direct XML Links, Displaying Many Meters on One Page
WebXML
Creates Real Time Data in XML Format. WebXML allows the Nexus meter to gather data from the Nexus Host or through other meters and put the data directly into an XML format. This allows you to share data through the web with multiple applications and create custom webpages, using WebExplorer.
WebXML technology is easy to configure and extremely flexible. With WebXML, your data is instantly available to a host of software applications including Internet Explorer, Excel, Power Point and Word.
Automatically Process and Present Data In Readable XML Format
Add Scale Factors, Multipliers or Other Desired html Capability
Display Data From Host Meter and/or Any Other Meter Using Modbus RTU or TCP/IP (WebReacher)
Customized Programming
Easily Viewed By Different Applications
Modbus Data Concentrator
[Dial Out ]
[Logic Dial-Out]
[Visual Alarm]
[Dial-In Server Capabilities]
WebReacher
With EIG's exclusive WebReacher technology, you can now access remote meters around the world, retrieve data and consolidate it onto one webpage or website without any separate software SCADA package or client-side ActiveX controls or Java applets.
No Additional Software Application Costs
No Server System Required
No Complex Integration
No Costly Point Charges (Up to 32 Devices)
WebAlarm – Email Alerts
EIG's WebAlarm sends real time email alerts via the Internet to up to 9 recipients simultaneously for any combination of event notifications.
Real Time Alerts
Simultaneous Emails to Multiple Recipients
Update Users on Virtually Any Abnormality
Uses Standard SMTP — Just Assign Email Addresses
Shows the Last 10 Emails on Website for Later Investigatio
Webdnp
Using this feature, you can gain access to the meter speaking native DNP over Ethernet. This allows the unit to open an exclusive network socket for DNP 3.0. Using this unique technology, all other meter web features are available simultaneously. Even with DNP 3.0 over the Ethernet, you still have access to multiple Modbus sockets, email alarms, web servers and many other communication features.
Webmod
(Open Architecture 3rd Party Integration) The 10/100BaseT design allows the unit to speak with 12 simultaneous sockets of Modbus TCP. EIG's WebMod features Modbus TCP open protocol that can be easily integrated with most other software or hardware. And, with the built-in Modbus data concentrator, you can poll up to 8 devices or 512 unique polling items from any device that can speak Modbus RTU and/or Modbus TCP protocols.
The processing capability and accuracy of the Nexus 1272 makes it possible to gather power quality information with unmatched precision. The Nexus 1272 is ideally suited for application on all critical loads. From health care to micro-electronics, the 1272 has what it takes to capture every anomaly. This insures that when there is a power problem, you have the information required to act. All Power Quality logs are time stamped to the nearest millisecond to insure accurate recording. Nexus' Advanced Download Logic collects only new data to minimize download times.
Event/Out of Limit Log
Records 1024 Events
Out of Limit Recording
High-Speed Input Event Recording
Outage Detection
Extensive Limit Setting Capabilities with Multiple Limits per Selected Quantity
Waveform Log
The waveform recording capability of the Nexus is unparalleled by any meter. Waveform records of this quality have historically been reserved only for transmission lines. The power of the Nexus 1272 now makes this quality available to your critical customers.
Extraordinary Resolution through 16 bit A/D Input
Sample Rates from 16 to 512 Samples per Cycle
Total Recording Times over 100 Seconds
Up to Six Channels
Voltage and Current Triggers
External Event Trigger
Voltage Surge/Sag Recording
Current Fault Analysis
Waveform Log
[Waveform Log]
[Waveform Log]
Harmonic Distortion Analysis
Log Harmonics into Historical Log for Later Analysis
Recorded Waveforms Provide Harmonics to the 255th Order
View Waveform Record
Harmonic Distortion Analysis
[Harmonic Distortion Analysis]
[Harmonic Distortion Analysis]
CBEMA/ITIC Log
The separate CBEMA/ITIC Log captures all voltage transients that fall outside these standards. The onboard log holds 1024 events. The data is downloaded to a separate log in the meter database for easy analysis. See all voltage disturbances on one screen through the Communicator EXT software.
Sag/Swell Analysis
Transient Recording